Following Government guidelines we are currently working with each promoter to secure dates in the future. Stay tuned for more information.

Search for an event by

Gleneagle INEC Arena

INEC Killarney is now officially rebranded as The Gleneagle INEC Arena following an investment in production and technology and an increase of patron capacity.7

The Gleneagle INEC Arena rebrand has come about as a result of investing over half a million euros in production and technology, across lighting, sound, and audio-visual systems, and an increased patron capacity of 4142.  This means that they now have the infrastructure to cater to a wider variety of acts and artists.

Speaking on the Gleneagle INEC Arena rebrand Mark Egan said “This was a very important project for us – The re-branding of the venue to the Gleneagle INEC Arena accurately reflects the product on offer. Our new arena capacity coupled with our technological infrastructure enables us to cater for bigger and better touring productions which in turn provides a better customer and artist experience.  The feedback from the artists that play here is always really positive.    There is a certain kind of energy here, not replicated anywhere else.”

Venue Spec

Main theatre stage
Main theatre stage
  • 2 Large dressing rooms are available situated under the stage. Toilet and show facilities in each
  • A paging system is installed between prompt corner and dressing rooms, this allows show relay and paging calls. Paging calls operate on a volume over-ride. Phone point fitted in each dressing room.
Dressing Rooms
Dressing Rooms
Communications
Communications
  • TECPRO ring intercom, stage and auditorium wired for twin rig operation PSU in control room.
  • 1 of 2 wire to 4 wire interface
  • All outlets wired 3 pin XLR male

Main supplies
Main supplies
  • 1 of 63A 3-Phase supply – DSL (normally motor supply) terminated in 63A 3 Phase CEEform
  • 1 of 63A 3-Phase supply – USR (normally for Outside Broadcast use) terminated in 63A 3Phase CCE from
  • 1 of 12A 3-Phase – USR (normally temp. dimmer supply) terminated in 125A 3-Phase CEEform, c/w 125A 3Phase CEEform male connector
  • 1 of 250A 3-Phase Power lock on DSR Fly Floor

Sound supply is 125A Single Phase, clean earth, switched in the amplifier room (above prompt corner) and distributed as follows:

  • 63A Ceeform DSL
  • 63A Supply in amplifier room
  • 32A Supply to Balcony mixing position
  • 32A Supply to Control Room
  • 1 of 32A 3-Phase supply – Auditorium Right loading bay (normally for seating hoverpad units), terminated in 2 x 16A 3-Phase CEE forms
To hire this venue, please contact
Fiona O’Connor

00353 86 929 2622 fiona.oconnor@inec.ie

For detailed technical specifications, please contact
Kieran Somers

00353 87 7708709 kieran.somers@inec.ie

Our sponsors